Sign In | Join Free | My burrillandco.com
Home > PLC SIMATIC S7-1500 >

SIEMENS 6ES7518-4FX00-1AB0 PROFINET RT, 3RD INTERFACE: ETHERNET, 4TH INTERFACE: PROFIBUS, 1 NS BIT PERFORMANCE, SIMATIC

    Buy cheap SIEMENS 6ES7518-4FX00-1AB0 PROFINET RT, 3RD INTERFACE: ETHERNET, 4TH INTERFACE: PROFIBUS, 1 NS BIT PERFORMANCE, SIMATIC from wholesalers
     
    Buy cheap SIEMENS 6ES7518-4FX00-1AB0 PROFINET RT, 3RD INTERFACE: ETHERNET, 4TH INTERFACE: PROFIBUS, 1 NS BIT PERFORMANCE, SIMATIC from wholesalers
    • Buy cheap SIEMENS 6ES7518-4FX00-1AB0 PROFINET RT, 3RD INTERFACE: ETHERNET, 4TH INTERFACE: PROFIBUS, 1 NS BIT PERFORMANCE, SIMATIC from wholesalers

    SIEMENS 6ES7518-4FX00-1AB0 PROFINET RT, 3RD INTERFACE: ETHERNET, 4TH INTERFACE: PROFIBUS, 1 NS BIT PERFORMANCE, SIMATIC

    Ask Lasest Price
    Brand Name : SIEMENS
    Model Number : 6ES7518-4FX00-1AB0
    Certification : CE
    Price : USD
    Payment Terms : L/C, T/T
    Supply Ability : 100
    Delivery Time : 10-12Days
    • Product Details
    • Company Profile

    SIEMENS 6ES7518-4FX00-1AB0 PROFINET RT, 3RD INTERFACE: ETHERNET, 4TH INTERFACE: PROFIBUS, 1 NS BIT PERFORMANCE, SIMATIC

    SIEMENS 6ES7518-4FX00-1AB0 PROFINET RT, 3RD INTERFACE: ETHERNET, 4TH INTERFACE: PROFIBUS, 1 NS BIT PERFORMANCE, SIMATIC

    Understood. Here are the key details about the SIEMENS 6ES7518-4FX00-1AB0 PROFINET RT controller module:

    Product Description:
    - The 6ES7518-4FX00-1AB0 is a SIMATIC S7-1500 CPU module with PROFINET RT (Real-Time) and PROFIBUS connectivity.
    - It features 3 Ethernet interfaces for PROFINET RT communication and a 4th interface for PROFIBUS with 1ns bit performance.
    - This module, like the previous ones, requires a SIMATIC memory card for program storage and additional functionality.

    Key Features:
    - PROFINET RT (Real-Time) services for deterministic, time-critical Ethernet-based communication.
    - 3 x Ethernet interfaces for PROFINET RT connectivity.
    - 4th interface for PROFIBUS with 1ns bit performance for high-speed, deterministic communication.
    - Suitable for time-critical applications such as motion control and manufacturing processes.
    - Integrated PROFIBUS master functionality.
    - Requires a SIMATIC memory card for program storage and additional features.
    - Powerful CPU with 4 MB work memory and 20 MB load memory.

    Connectivity:
    - 3 x Ethernet/PROFINET RT interfaces for deterministic, real-time Ethernet communication.
    - 1 x PROFIBUS interface for connecting PROFIBUS devices and networks.

    Performance:
    - 1ns bit performance on the PROFIBUS interface for high-speed, deterministic communication.
    - Enables precise control and synchronization of connected devices.

    SIMATIC Memory Card:
    - The 6ES7518-4FX00-1AB0 module requires a SIMATIC memory card for program storage and additional functionality.
    - The memory card provides the necessary storage capacity and enables features like firmware updates, backup, and restore functionality.

    Certifications:
    - According to the information available, the 6ES7518-4FX00-1AB0 module likely has relevant industrial certifications and approvals, such as:
    - IEC 61131-2 (Programmable controllers)
    - IEC 61784-2 (PROFINET)
    - UL Recognized Component marking
    - Hazardous Locations approvals (e.g., Class I, Division 2)
    - Marine classification society approvals

    In summary, the SIEMENS 6ES7518-4FX00-1AB0 is a PROFINET RT and PROFIBUS controller module with 1ns bit performance on the PROFIBUS interface, designed for high-speed, deterministic communication in SIMATIC S7-1500 automation systems. It requires a SIMATIC memory card for program storage and additional functionality.

    General information
    Product type designationCPU 1518F-4 PN/DP MFP
    HW functional statusFS03
    Firmware versionV2.9
    Product function
    ● I&M dataYes; I&M0 to I&M3
    ● Isochronous modeYes; Distributed and central; with minimum OB 6x cycle of 125 µs (distributed) and 1 ms (central)
    Engineering with
    ● STEP 7 TIA Portal configurable/integrated from versionV17 (FW V2.9) / V15 (FW V2.5) or higher
    Configuration control
    via datasetYes
    Display
    Screen diagonal [cm]6.1 cm
    Control elements
    Number of keys6
    Mode selector switch1
    Supply voltage
    Rated value (DC)24 V
    permissible range, lower limit (DC)19.2 V
    permissible range, upper limit (DC)28.8 V
    Reverse polarity protectionYes
    Mains buffering
    ● Mains/voltage failure stored energy time5 ms
    Input current
    Current consumption (rated value)1.7 A
    Current consumption, max.2 A
    Inrush current, max.2.7 A; Rated value
    I²t0.02 A²·s
    Power
    Infeed power to the backplane bus12 W
    Power consumption from the backplane bus (balanced)35 W
    Power loss
    Power loss, typ.29 W
    Memory
    Number of slots for SIMATIC memory card1
    SIMATIC memory card requiredYes
    Work memory
    ● integrated (for program)9 Mbyte
    ● integrated (for data)60 Mbyte
    ● integrated (for CPU function library of CPU Runtime)50 Mbyte; Note: The "CPU function library of the CPU" are C/C++ blocks for the user program that were created using the SIMATIC ODK 1500S or Target 1500S.
    Working memory for additional functions
    ● Integrated (for C/C++ Runtime application)512 Mbyte
    ● available (for Linux runtime application)1 Gbyte
    Load memory
    ● Plug-in (SIMATIC Memory Card), max.32 Gbyte; the memory card must have at least 2 GB of space on it
    Backup
    ● maintenance-freeYes
    CPU processing times
    for bit operations, typ.1 ns
    for word operations, typ.2 ns
    for fixed point arithmetic, typ.2 ns
    for floating point arithmetic, typ.6 ns
    CPU-blocks
    Number of elements (total)20 000; Blocks (OB, FB, FC, DB) and UDTs
    DB
    ● Number range1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999
    ● Size, max.16 Mbyte; For DBs with absolute addressing, the max. size is 64 KB
    FB
    ● Number range0 ... 65 535
    ● Size, max.1 Mbyte
    FC
    ● Number range0 ... 65 535
    ● Size, max.1 Mbyte
    OB
    ● Size, max.1 Mbyte
    ● Number of free cycle OBs100
    ● Number of time alarm OBs20
    ● Number of delay alarm OBs20
    ● Number of cyclic interrupt OBs20; With Failsafe, two RTGs with one "Cyclic interrupt OB" or one "Free cycle OB" (F-OB) each are possible
    ● Number of process alarm OBs50
    ● Number of DPV1 alarm OBs3
    ● Number of isochronous mode OBs3
    ● Number of technology synchronous alarm OBs2
    ● Number of startup OBs100
    ● Number of asynchronous error OBs4
    ● Number of synchronous error OBs2
    ● Number of diagnostic alarm OBs1
    Nesting depth
    ● per priority class24
    Counters, timers and their retentivity
    S7 counter
    ● Number2 048
    Retentivity
    — adjustableYes
    IEC counter
    ● NumberAny (only limited by the main memory)
    Retentivity
    — adjustableYes
    S7 times
    ● Number2 048
    Retentivity
    — adjustableYes
    IEC timer
    ● NumberAny (only limited by the main memory)
    Retentivity
    — adjustableYes
    Data areas and their retentivity
    Retentive data area (incl. timers, counters, flags), max.768 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 700 KB
    Extended retentive data area (incl. timers, counters, flags), max.20 Mbyte; When using PS 6 0W 24/48/60 V DC HF
    Flag
    ● Size, max.16 kbyte
    ● Number of clock memories8; 8 clock memory bit, grouped into one clock memory byte
    Data blocks
    ● Retentivity adjustableYes
    ● Retentivity presetNo
    Local data
    ● per priority class, max.64 kbyte; max. 16 KB per block
    Address area
    Number of IO modules16 384; max. number of modules / submodules
    I/O address area
    ● Inputs32 kbyte; All inputs are in the process image
    ● Outputs32 kbyte; All outputs are in the process image
    per integrated IO subsystem
    — Inputs (volume)32 kbyte; max. 32 KB via X1; max. 8 KB via X2 or X4
    — Outputs (volume)32 kbyte; max. 32 KB via X1; max. 8 KB via X2 or X4
    per CM/CP
    — Inputs (volume)8 kbyte
    — Outputs (volume)8 kbyte
    Subprocess images
    ● Number of subprocess images, max.32
    Hardware configuration
    Number of distributed IO systems64; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS communication modules, but also by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link)
    Number of DP masters
    ● integrated1
    ● Via CM8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total
    Number of IO Controllers
    ● integrated2
    ● Via CM8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total
    Rack
    ● Modules per rack, max.32; CPU + 31 modules
    PtP CM
    ● Number of PtP CMsthe number of connectable PtP CMs is only limited by the number of available slots
    Time of day
    Clock
    ● TypeHardware clock
    ● Backup time6 wk; At 40 °C ambient temperature, typically
    ● Deviation per day, max.10 s; Typ.: 2 s
    Operating hours counter
    ● Number16
    Clock synchronization
    ● supportedYes
    ● to DP, masterYes
    ● in AS, masterYes
    ● in AS, slaveYes
    ● on Ethernet via NTPYes
    Interfaces
    Number of PROFINET interfaces3
    Number of PROFIBUS interfaces1
    1. Interface
    Interface types
    ● RJ 45 (Ethernet)Yes; X1
    ● Number of ports2
    ● integrated switchYes
    Protocols
    ● IP protocolYes; IPv4
    ● PROFINET IO ControllerYes
    ● PROFINET IO DeviceYes
    ● SIMATIC communicationYes
    ● Open IE communicationYes; Optionally also encrypted
    ● Web serverYes
    ● Media redundancyYes; MRP Automanager according to IEC 62439-2 Edition 2.0
    PROFINET IO Controller
    Services
    — PG/OP communicationYes
    — Isochronous modeYes
    — Direct data exchangeYes; Requirement: IRT and isochronous mode (MRPD optional)
    — IRTYes
    — PROFIenergyYes; per user program
    — Prioritized startupYes; Max. 32 PROFINET devices
    — Number of connectable IO Devices, max.512; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
    — Of which IO devices with IRT, max.64
    — Number of connectable IO Devices for RT, max.512
    — of which in line, max.512
    — Number of IO Devices that can be simultaneously activated/deactivated, max.8; in total across all interfaces
    — Number of IO Devices per tool, max.8
    — Updating timesThe minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
    Update time for IRT
    — for send cycle of 125 µs125 µs
    — for send cycle of 187.5 µs187.5 µs
    — for send cycle of 250 µs250 µs to 4 ms
    — for send cycle of 500 µs500 µs to 8 ms
    — for send cycle of 1 ms1 ms to 16 ms
    — for send cycle of 2 ms2 ms to 32 ms
    — for send cycle of 4 ms4 ms to 64 ms
    — With IRT and parameterization of "odd" send cyclesUpdate time = set "odd" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs)
    Update time for RT
    — for send cycle of 250 µs250 µs to 128 ms
    — for send cycle of 500 µs500 µs to 256 ms
    — for send cycle of 1 ms1 ms to 512 ms
    — for send cycle of 2 ms2 ms to 512 ms
    — for send cycle of 4 ms4 ms to 512 ms
    PROFINET IO Device
    Services
    — PG/OP communicationYes
    — Isochronous modeNo
    — IRTYes; Minimum send cycle of 250 µs
    — PROFIenergyYes; per user program
    — Shared deviceYes
    — Number of IO Controllers with shared device, max.4
    — activation/deactivation of I-devicesYes; per user program
    — Asset management recordYes; per user program
    2. Interface
    Interface types
    ● RJ 45 (Ethernet)Yes; X2
    ● Number of ports1
    ● integrated switchNo
    Protocols
    ● IP protocolYes; IPv4
    ● PROFINET IO ControllerYes
    ● PROFINET IO DeviceYes
    ● SIMATIC communicationYes
    ● Open IE communicationYes; Optionally also encrypted
    ● Web serverYes
    ● Media redundancyNo
    PROFINET IO Controller
    Services
    — PG/OP communicationYes
    — Isochronous modeNo
    — Direct data exchangeNo
    — IRTNo
    — PROFIenergyYes; per user program
    — Prioritized startupNo
    — Number of connectable IO Devices, max.128; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
    — Number of connectable IO Devices for RT, max.128
    — of which in line, max.128
    — Number of IO Devices that can be simultaneously activated/deactivated, max.8; in total across all interfaces
    — Number of IO Devices per tool, max.8
    — Updating timesThe minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
    Update time for RT
    — for send cycle of 1 ms1 ms to 512 ms
    PROFINET IO Device
    Services
    — PG/OP communicationYes
    — Isochronous modeNo
    — IRTNo
    — PROFIenergyYes; per user program
    — Prioritized startupNo
    — Shared deviceYes
    — Number of IO Controllers with shared device, max.4
    — activation/deactivation of I-devicesYes; per user program
    — Asset management recordYes; per user program

    SIEMENS 6ES7518-4FX00-1AB0 PROFINET RT, 3RD INTERFACE: ETHERNET, 4TH INTERFACE: PROFIBUS, 1 NS BIT PERFORMANCE, SIMATIC

    Quality SIEMENS 6ES7518-4FX00-1AB0 PROFINET RT, 3RD INTERFACE: ETHERNET, 4TH INTERFACE: PROFIBUS, 1 NS BIT PERFORMANCE, SIMATIC for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Voboal Industrial Automation Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)