Sign In | Join Free | My burrillandco.com
Home > PLC SIMATIC S7-1500 >

SIEMENS 6ES7512-1SK01-0AB0 SIMATIC MEMORY CARD REQUIRED, BUSADAPTER REQUIRED FOR PORT 1 AND 2

    Buy cheap SIEMENS 6ES7512-1SK01-0AB0 SIMATIC MEMORY CARD REQUIRED, BUSADAPTER REQUIRED FOR PORT 1 AND 2 from wholesalers
     
    Buy cheap SIEMENS 6ES7512-1SK01-0AB0 SIMATIC MEMORY CARD REQUIRED, BUSADAPTER REQUIRED FOR PORT 1 AND 2 from wholesalers
    • Buy cheap SIEMENS 6ES7512-1SK01-0AB0 SIMATIC MEMORY CARD REQUIRED, BUSADAPTER REQUIRED FOR PORT 1 AND 2 from wholesalers

    SIEMENS 6ES7512-1SK01-0AB0 SIMATIC MEMORY CARD REQUIRED, BUSADAPTER REQUIRED FOR PORT 1 AND 2

    Ask Lasest Price
    Brand Name : SIEMENS
    Model Number : 6ES7512-1SK01-0AB0
    Certification : CE
    Price : USD
    Payment Terms : L/C, T/T
    Supply Ability : 100
    Delivery Time : 10-12Days
    • Product Details
    • Company Profile

    SIEMENS 6ES7512-1SK01-0AB0 SIMATIC MEMORY CARD REQUIRED, BUSADAPTER REQUIRED FOR PORT 1 AND 2

    SIEMENS 6ES7512-1SK01-0AB0 SIMATIC MEMORY CARD REQUIRED, BUSADAPTER REQUIRED FOR PORT 1 AND 2

    Understood, the details you provided are for the SIEMENS 6ES7512-1SK01-0AB0 SIMATIC S7-1500 CPU module:

    Product Description:
    - The 6ES7512-1SK01-0AB0 is a SIMATIC S7-1500 CPU module.
    - It requires a SIMATIC memory card for program storage and additional functionality.
    - Busadapters are required for the module's Port 1 and Port 2 interfaces.

    Key Features:
    - SIMATIC S7-1500 CPU module with specific processing capabilities.
    - Requires a SIMATIC memory card for program storage, firmware updates, and other advanced features.
    - Supports the use of busadapters for the module's communication ports.

    Connectivity:
    - The module has at least 2 communication ports (Port 1 and Port 2) that require busadapters for connectivity.
    - The busadapters enable the use of various communication protocols and fieldbus systems, such as PROFINET, PROFIBUS, or other industrial Ethernet standards.

    SIMATIC Memory Card:
    - The 6ES7512-1SK01-0AB0 module requires a SIMATIC memory card for program storage, firmware updates, and additional functionality.
    - The memory card provides the necessary storage capacity and enables advanced features of the CPU module.

    Busadapters:
    - Busadapters are required for the module's Port 1 and Port 2 communication interfaces.
    - These adapters allow the CPU module to connect to and communicate over different industrial communication networks and fieldbuses.

    Approvals and Certifications:
    - As a SIMATIC S7-1500 CPU module, the 6ES7512-1SK01-0AB0 likely has relevant industrial certifications and approvals, such as:
    - IEC 61131-2 (Programmable controllers)
    - IEC 61784-2 (PROFINET)
    - UL Recognized Component marking
    - Hazardous Locations approvals (e.g., Class I, Division 2)
    - Marine classification society approvals (e.g., DNV GL, ABS, LR, etc.)
    - Any other relevant industry-specific certifications and standards required for the intended application and geography.

    Please let me know if I have accurately summarized the key details of the SIEMENS 6ES7512-1SK01-0AB0 SIMATIC S7-1500 CPU module.

    General information
    Product type designationCPU 1512SP F-1 PN
    HW functional statusFS05
    Firmware versionV2.9
    Product function
    ● I&M dataYes; I&M0 to I&M3
    ● Module swapping during operation (hot swapping)Yes; Multi-hot swapping
    ● Isochronous modeYes; Only with PROFINET; with minimum OB 6x cycle of 625 µs
    Engineering with
    ● STEP 7 TIA Portal configurable/integrated from versionV17 (FW V2.9) / V13 SP1 Update 4 (FW V1.8) or higher
    Configuration control
    via datasetYes
    Control elements
    Mode selector switch1
    Supply voltage
    Rated value (DC)24 V
    permissible range, lower limit (DC)19.2 V
    permissible range, upper limit (DC)28.8 V
    Reverse polarity protectionYes
    Mains buffering
    ● Mains/voltage failure stored energy time5 ms
    Input current
    Current consumption (rated value)0.6 A
    Current consumption, max.0.9 A
    Inrush current, max.4.7 A; Rated value
    I²t0.14 A²·s
    Power
    Infeed power to the backplane bus8.75 W
    Power loss
    Power loss, typ.5.6 W
    Memory
    Number of slots for SIMATIC memory card1
    SIMATIC memory card requiredYes
    Work memory
    ● integrated (for program)300 kbyte
    ● integrated (for data)1 Mbyte
    Load memory
    ● Plug-in (SIMATIC Memory Card), max.32 Gbyte
    Backup
    ● maintenance-freeYes
    CPU processing times
    for bit operations, typ.48 ns
    for word operations, typ.58 ns
    for fixed point arithmetic, typ.77 ns
    for floating point arithmetic, typ.307 ns
    CPU-blocks
    Number of elements (total)4 000; Blocks (OB, FB, FC, DB) and UDTs
    DB
    ● Number range1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999
    ● Size, max.1 Mbyte; For DBs with absolute addressing, the max. size is 64 KB
    FB
    ● Number range0 ... 65 535
    ● Size, max.200 kbyte
    FC
    ● Number range0 ... 65 535
    ● Size, max.200 kbyte
    OB
    ● Size, max.200 kbyte
    ● Number of free cycle OBs100
    ● Number of time alarm OBs20
    ● Number of delay alarm OBs20
    ● Number of cyclic interrupt OBs20; With minimum OB 3x cycle of 500 µs
    ● Number of process alarm OBs50
    ● Number of DPV1 alarm OBs3
    ● Number of isochronous mode OBs1
    ● Number of technology synchronous alarm OBs2
    ● Number of startup OBs100
    ● Number of asynchronous error OBs4
    ● Number of synchronous error OBs2
    ● Number of diagnostic alarm OBs1
    Nesting depth
    ● per priority class24; Up to 8 possible for F-blocks
    Counters, timers and their retentivity
    S7 counter
    ● Number2 048
    Retentivity
    — adjustableYes
    IEC counter
    ● NumberAny (only limited by the main memory)
    Retentivity
    — adjustableYes
    S7 times
    ● Number2 048
    Retentivity
    — adjustableYes
    IEC timer
    ● NumberAny (only limited by the main memory)
    Retentivity
    — adjustableYes
    Data areas and their retentivity
    Retentive data area (incl. timers, counters, flags), max.128 kbyte; Available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 88 KB
    Flag
    ● Size, max.16 kbyte
    ● Number of clock memories8; 8 clock memory bit, grouped into one clock memory byte
    Data blocks
    ● Retentivity adjustableYes
    ● Retentivity presetNo
    Local data
    ● per priority class, max.64 kbyte; max. 16 KB per block
    Address area
    Number of IO modules2 048; max. number of modules / submodules
    I/O address area
    ● Inputs32 kbyte; All inputs are in the process image
    ● Outputs32 kbyte; All outputs are in the process image
    per integrated IO subsystem
    — Inputs (volume)8 kbyte
    — Outputs (volume)8 kbyte
    per CM/CP
    — Inputs (volume)8 kbyte
    — Outputs (volume)8 kbyte
    Subprocess images
    ● Number of subprocess images, max.32
    Address space per module
    ● Address space per module, max.288 byte; For input and output data respectively
    Address space per station
    ● Address space per station, max.2 560 byte; for central inputs and outputs; depending on configuration; 2 048 bytes for ET 200SP modules + 512 bytes for ET 200AL modules
    Hardware configuration
    Number of distributed IO systems32; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS communication modules, but also by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link)
    Number of DP masters
    ● Via CM1
    Number of IO Controllers
    ● integrated1
    ● Via CM0
    Rack
    ● Modules per rack, max.80; CPU + 64 modules + server module (mounting width max. 1 m) + 16 ET 200AL modules
    ● Quantity of operable ET 200SP modules, max.64
    ● Quantity of operable ET 200AL modules, max.16
    PtP CM
    ● Number of PtP CMsthe number of connectable PtP CMs is only limited by the number of available slots
    Time of day
    Clock
    ● TypeHardware clock
    ● Backup time6 wk; At 40 °C ambient temperature, typically
    ● Deviation per day, max.10 s; Typ.: 2 s
    Operating hours counter
    ● Number16
    Clock synchronization
    ● supportedYes
    ● to DP, masterYes; Via CM DP module
    ● to DP, slaveYes; Via CM DP module
    ● in AS, masterYes
    ● in AS, slaveYes
    ● on Ethernet via NTPYes
    Interfaces
    Number of PROFINET interfaces1
    Number of PROFIBUS interfaces1; Via CM DP module
    Optical interfaceYes; via BusAdapter
    1. Interface
    Interface types
    ● RJ 45 (Ethernet)Yes; X1 P3; opt. X1 P1 and X1 P2 via BusAdapter BA 2x RJ45
    ● Number of ports3; 1. integr. + 2. via BusAdapter
    ● integrated switchYes
    ● BusAdapter (PROFINET)Yes; compatible BusAdapters: BA 2x RJ45, BA 2x FC, BA 2x M12
    Protocols
    ● IP protocolYes; IPv4
    ● PROFINET IO ControllerYes
    ● PROFINET IO DeviceYes
    ● SIMATIC communicationYes
    ● Open IE communicationYes; Optionally also encrypted
    ● Web serverYes
    ● Media redundancyYes; MRP Automanager according to IEC 62439-2 Edition 2.0
    PROFINET IO Controller
    Services
    — PG/OP communicationYes
    — Isochronous modeYes
    — Direct data exchangeYes; Requirement: IRT and isochronous mode (MRPD optional)
    — IRTYes
    — PROFIenergyYes; per user program
    — Prioritized startupYes; Max. 32 PROFINET devices
    — Number of connectable IO Devices, max.128; In total, up to 512 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
    — Of which IO devices with IRT, max.64
    — Number of connectable IO Devices for RT, max.128
    — of which in line, max.128
    — Number of IO Devices that can be simultaneously activated/deactivated, max.8; in total across all interfaces
    — Number of IO Devices per tool, max.8
    — Updating timesThe minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
    Update time for IRT
    — for send cycle of 250 µs250 μs to 4 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 500 µs of the isochronous OB is decisive
    — for send cycle of 500 µs500 µs to 8 ms
    — for send cycle of 1 ms1 ms to 16 ms
    — for send cycle of 2 ms2 ms to 32 ms
    — for send cycle of 4 ms4 ms to 64 ms
    — With IRT and parameterization of "odd" send cyclesUpdate time = set "odd" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs)
    Update time for RT
    — for send cycle of 250 µs250 µs to 128 ms
    — for send cycle of 500 µs500 µs to 256 ms
    — for send cycle of 1 ms1 ms to 512 ms
    — for send cycle of 2 ms2 ms to 512 ms
    — for send cycle of 4 ms4 ms to 512 ms
    PROFINET IO Device
    Services
    — PG/OP communicationYes
    — Isochronous modeNo
    — IRTYes
    — PROFIenergyYes; per user program
    — Shared deviceYes
    — Number of IO Controllers with shared device, max.4
    — activation/deactivation of I-devicesYes; per user program
    — Asset management recordYes; per user program
    2. Interface
    Interface types
    ● RS 485Yes; Via CM DP module
    ● Number of ports1
    Protocols
    ● PROFIBUS DP masterYes
    ● PROFIBUS DP slaveYes
    ● SIMATIC communicationYes
    PROFIBUS DP master
    ● Number of connections, max.48; Of which 4 each reserved for ES and HMI
    ● Number of DP slaves, max.125; In total, up to 512 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
    Services
    — PG/OP communicationYes
    — EquidistanceNo
    — Isochronous modeNo
    — Activation/deactivation of DP slavesYes
    Interface types
    RJ 45 (Ethernet)
    ● 100 MbpsYes
    ● AutonegotiationYes
    ● AutocrossingYes
    ● Industrial Ethernet status LEDYes
    RS 485
    ● Transmission rate, max.12 Mbit/s
    Protocols
    PROFIsafeYes; V2.4 / V2.6
    Number of connections
    ● Number of connections, max.128; via integrated interfaces of the CPU and connected CPs / CMs
    ● Number of connections reserved for ES/HMI/web10
    ● Number of connections via integrated interfaces88
    ● Number of connections per CP/CM32
    ● Number of S7 routing paths16
    Redundancy mode
    ● H-Sync forwardingYes
    Media redundancy
    — Media redundancyYes; only via BusAdapter
    — MRPYes; MRP Automanager according to IEC 62439-2 Edition 2.0, MRP Manager; MRP Client
    — MRP interconnection, supportedYes; as MRP ring node according to IEC 62439-2 Edition 3.0
    — MRPDYes; Requirement: IRT
    — Switchover time on line break, typ.200 ms; For MRP, bumpless for MRPD
    — Number of stations in the ring, max.50
    SIMATIC communication
    ● PG/OP communicationYes; encryption with TLS V1.3 pre-selected
    ● S7 routingYes
    ● Data record routingYes
    ● S7 communication, as serverYes
    ● S7 communication, as clientYes
    ● User data per job, max.See online help (S7 communication, user data size)
    Open IE communication
    ● TCP/IPYes
    — Data length, max.64 kbyte
    — several passive connections per port, supportedYes
    ● ISO-on-TCP (RFC1006)Yes
    — Data length, max.64 kbyte
    ● UDPYes
    — Data length, max.2 kbyte; 1 472 bytes for UDP broadcast
    — UDP multicastYes; Max. 5 multicast circuits
    ● DHCPYes
    ● DNSYes
    ● SNMPYes
    ● DCPYes
    ● LLDPYes
    ● EncryptionYes; Optional
    Web server
    ● HTTPYes; Standard and user pages
    ● HTTPSYes; Standard and user pages
    OPC UA
    ● Runtime license requiredYes
    ● OPC UA ClientYes
    — Application authenticationYes
    — Security policiesAvailable security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256
    — User authentication"anonymous" or by user name & password
    — Number of connections, max.4
    — Number of nodes of the client interfaces, recommended max.1 000
    — Number of elements for one call of OPC_UA_NodeGetHandleList/OPC_UA_ReadList/OPC_UA_WriteList, max.300
    — Number of elements for one call of OPC_UA_NameSpaceGetIndexList, max.20
    — Number of elements for one call of OPC_UA_MethodGetHandleList, max.100
    — Number of simultaneous calls of the client instructions for session management, per connection, max.1
    — Number of simultaneous calls of the client instructions for data access, per connection, max.5
    — Number of registerable nodes, max.5 000
    — Number of registerable method calls of OPC_UA_MethodCall, max.100
    — Number of inputs/outputs when calling OPC_UA_MethodCall, max.20
    ● OPC UA ServerYes; Data access (read, write, subscribe), method call, custom address space
    — Application authenticationYes
    — Security policiesAvailable security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256
    — User authentication"anonymous" or by user name & password
    — Number of sessions, max.32
    — Number of accessible variables, max.50 000
    — Number of registerable nodes, max.10 000
    — Number of subscriptions per session, max.20
    — Sampling interval, min.100 ms
    — Publishing interval, min.500 ms
    — Number of server methods, max.20
    — Number of inputs/outputs per server method, max.20
    — Number of monitored items, recommended max.1 000; for 1 s sampling interval and 1 s send interval
    — Number of server interfaces, max.10 of each "Server interfaces" / "Companion specification" type and 20 of the type "Reference namespace"
    — Number of nodes for user-defined server interfaces, max.1 000

    SIEMENS 6ES7512-1SK01-0AB0 SIMATIC MEMORY CARD REQUIRED, BUSADAPTER REQUIRED FOR PORT 1 AND 2

    Quality SIEMENS 6ES7512-1SK01-0AB0 SIMATIC MEMORY CARD REQUIRED, BUSADAPTER REQUIRED FOR PORT 1 AND 2 for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Voboal Industrial Automation Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)