    Simatic Siemens PLC ET 200 IP65 Memory Card 6ES7513-2GL00-0AB0

    Ask Lasest Price
    Brand Name : SIEMENS
    Model Number : 6ES7513-2GL00-0AB0
    Certification : CE
    Price : USD
    Payment Terms : L/C, T/T
    Supply Ability : 100
    Delivery Time : 10-12Days
    • Product Details
    • Company Profile

    Simatic Siemens PLC ET 200 IP65 Memory Card 6ES7513-2GL00-0AB0

    SIEMENS 6ES7513-2GL00-0AB0 DEGREE OF PROTECTION: IP65/67, SIMATIC MEMORY CARD REQUIRED CONNECTION MODULE REQUIRED

    Okay, got it. The details you provided are for the SIEMENS 6ES7513-2GL00-0AB0 SIMATIC S7-1500 CPU module:

    Product Description:
    - The 6ES7513-2GL00-0AB0 is a SIMATIC S7-1500 CPU module.
    - It has a degree of protection of IP65/67, which means it is dust-tight and protected against the effects of temporary immersion in water.
    - A SIMATIC memory card is required for program storage and additional functionality.
    - A connection module is required for interfacing the CPU module.

    Key Features:
    - SIMATIC S7-1500 CPU module with specific processing capabilities.
    - Rated with a high degree of protection, IP65/67, making it suitable for use in harsh environments.
    - Requires a SIMATIC memory card for program storage, firmware updates, and other advanced features.
    - Requires a connection module for interfacing and connecting the CPU module.

    Degree of Protection:
    - The 6ES7513-2GL00-0AB0 module has a degree of protection of IP65/67.
    - IP65 means the module is dust-tight and protected against low-pressure water jets from any direction.
    - IP67 means the module is protected against the effects of temporary immersion in water up to 1 meter in depth.
    - This high level of protection makes the module suitable for use in industrial environments with high levels of dust and moisture.

    SIMATIC Memory Card:
    - The 6ES7513-2GL00-0AB0 module requires a SIMATIC memory card for program storage, firmware updates, and additional functionality.
    - The memory card provides the necessary storage capacity and enables advanced features of the CPU module.

    Connection Module:
    - A connection module is required for interfacing and connecting the 6ES7513-2GL00-0AB0 CPU module.
    - The connection module allows for the installation and wiring of the CPU module within the application.

    Approvals and Certifications:
    - As a SIMATIC S7-1500 CPU module, the 6ES7513-2GL00-0AB0 likely has relevant industrial certifications and approvals, such as:
    - IEC 61131-2 (Programmable controllers)
    - IEC 61784-2 (PROFINET)
    - UL Recognized Component marking
    - Hazardous Locations approvals (e.g., Class I, Division 2)
    - Marine classification society approvals (e.g., DNV GL, ABS, LR, etc.)
    - Any other relevant industry-specific certifications and standards required for the intended application and geography.

    Please let me know if I have accurately summarized the key details of the SIEMENS 6ES7513-2GL00-0AB0 SIMATIC S7-1500 CPU module, including the degree of protection, required memory card, and connection module.

    General information
    Product type designationCPU 1513pro F-2 PN
    HW functional statusFS01
    Firmware versionV2.8
    Product function
    ● I&M dataYes; I&M0 to I&M3
    ● Isochronous modeYes; Via X1, with minimum OB 6x cycle of 500 µs
    Engineering with
    ● STEP 7 TIA Portal configurable/integrated from versionV16
    Configuration control
    via datasetYes
    Control elements
    Mode selector switch1
    Supply voltage
    permissible range, lower limit (DC)20.4 V
    permissible range, upper limit (DC)28.8 V
    Reverse polarity protectionYes
    Mains buffering
    ● Mains/voltage failure stored energy time5 ms
    Input current
    Current consumption (rated value)0.31 A
    Inrush current, max.0.4 A; Rated value
    I²t0.001 A²·s
    from supply voltage 1L+, max.0.35 A
    Power
    Infeed power to the backplane bus2.275 W
    Power loss
    Power loss, typ.5.3 W
    Memory
    Number of slots for SIMATIC memory card1
    SIMATIC memory card requiredYes
    Work memory
    ● integrated (for program)450 kbyte
    ● integrated (for data)1.5 Mbyte
    Load memory
    ● Plug-in (SIMATIC Memory Card), max.32 Gbyte
    Backup
    ● maintenance-freeYes
    CPU processing times
    for bit operations, typ.40 ns
    for word operations, typ.48 ns
    for fixed point arithmetic, typ.64 ns
    for floating point arithmetic, typ.256 ns
    CPU-blocks
    Number of elements (total)2 000; Blocks (OB, FB, FC, DB) and UDTs
    DB
    ● Number range1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999
    ● Size, max.1.5 Mbyte; For DBs with absolute addressing, the max. size is 64 KB
    FB
    ● Number range0 ... 65 535
    ● Size, max.450 kbyte
    FC
    ● Number range0 ... 65 535
    ● Size, max.450 kbyte
    OB
    ● Size, max.450 kbyte
    ● Number of free cycle OBs100
    ● Number of time alarm OBs20
    ● Number of delay alarm OBs20
    ● Number of cyclic interrupt OBs20; With minimum OB 3x cycle of 500 µs
    ● Number of process alarm OBs50
    ● Number of DPV1 alarm OBs3
    ● Number of isochronous mode OBs1
    ● Number of technology synchronous alarm OBs2
    ● Number of startup OBs100
    ● Number of asynchronous error OBs4
    ● Number of synchronous error OBs2
    ● Number of diagnostic alarm OBs1
    Nesting depth
    ● per priority class24
    Counters, timers and their retentivity
    S7 counter
    ● Number2 048
    Retentivity
    — adjustableYes
    IEC counter
    ● NumberAny (only limited by the main memory)
    Retentivity
    — adjustableYes
    S7 times
    ● Number2 048
    Retentivity
    — adjustableYes
    IEC timer
    ● NumberAny (only limited by the main memory)
    Retentivity
    — adjustableYes
    Data areas and their retentivity
    Retentive data area (incl. timers, counters, flags), max.128 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 88 KB
    Flag
    ● Size, max.16 kbyte
    ● Number of clock memories8; 8 clock memory bit, grouped into one clock memory byte
    Data blocks
    ● Retentivity adjustableYes
    ● Retentivity presetNo
    Local data
    ● per priority class, max.64 kbyte; max. 16 KB per block
    Address area
    Number of IO modules2 048; max. number of modules / submodules
    I/O address area
    ● Inputs32 kbyte; All inputs are in the process image
    ● Outputs32 kbyte; All outputs are in the process image
    per integrated IO subsystem
    — Inputs (volume)8 kbyte
    — Outputs (volume)8 kbyte
    Hardware configuration
    Number of distributed IO systems32; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS communication modules, but also by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link)
    Number of IO Controllers
    ● integrated2
    ● Via CM0
    Rack
    ● Modules per rack, max.16; Expansion width max. 1.2 m
    ● Number of lines, max.1
    Time of day
    Clock
    ● Backup time6 wk; At 40 °C ambient temperature, typically
    ● Deviation per day, max.10 s; Typ.: 2 s
    Operating hours counter
    ● Number16
    Clock synchronization
    ● supportedYes
    ● in AS, masterYes
    ● in AS, slaveYes
    ● on Ethernet via NTPYes
    Interfaces
    Number of PROFINET interfaces2
    Number of PROFIBUS interfaces0
    1. Interface
    Interface types
    ● RJ 45 (Ethernet)Yes; X1 P3
    ● Number of ports3; 2x M12 + 1x RJ45
    ● integrated switchYes
    Protocols
    ● IP protocolYes; IPv4
    ● PROFINET IO ControllerYes
    ● PROFINET IO DeviceYes
    ● SIMATIC communicationYes
    ● Open IE communicationYes; Optionally also encrypted
    ● Web serverYes
    ● Media redundancyYes; MRP Automanager according to IEC 62439-2 Edition 2.0
    PROFINET IO Controller
    Services
    — PG/OP communicationYes
    — Isochronous modeYes
    — Direct data exchangeYes; Requirement: IRT and isochronous mode (MRPD optional)
    — IRTYes
    — PROFIenergyYes
    — Prioritized startupYes; Max. 32 PROFINET devices
    — Number of connectable IO Devices, max.128; In total, up to 512 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
    — Of which IO devices with IRT, max.64
    — Number of connectable IO Devices for RT, max.128
    — of which in line, max.128
    — Number of IO Devices that can be simultaneously activated/deactivated, max.8; in total across all interfaces
    — Number of IO Devices per tool, max.8
    — Updating timesThe minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
    Update time for IRT
    — for send cycle of 250 µs250 μs to 4 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 500 µs of the isochronous OB is decisive
    — for send cycle of 500 µs500 µs to 8 ms
    — for send cycle of 1 ms1 ms to 16 ms
    — for send cycle of 2 ms2 ms to 32 ms
    — for send cycle of 4 ms4 ms to 64 ms
    — With IRT and parameterization of "odd" send cyclesUpdate time = set "odd" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs)
    Update time for RT
    — for send cycle of 250 µs250 µs to 128 ms
    — for send cycle of 500 µs500 µs to 256 ms
    — for send cycle of 1 ms1 ms to 512 ms
    — for send cycle of 2 ms2 ms to 512 ms
    — for send cycle of 4 ms4 ms to 512 ms
    PROFINET IO Device
    Services
    — PG/OP communicationYes
    — Isochronous modeNo
    — IRTYes
    — PROFIenergyYes; per user program
    — Prioritized startupNo
    — Shared deviceYes
    — Number of IO Controllers with shared device, max.4
    — Asset management recordYes; per user program
    2. Interface
    Interface types
    ● RJ 45 (Ethernet)No
    ● Number of ports1; 1x M12
    ● integrated switchNo
    Protocols
    ● IP protocolYes; IPv4
    ● PROFINET IO ControllerYes
    ● PROFINET IO DeviceYes
    ● SIMATIC communicationYes
    ● Open IE communicationYes; Optionally also encrypted
    ● Web serverYes
    ● Media redundancyNo
    PROFINET IO Controller
    Services
    — PG/OP communicationYes
    — Isochronous modeNo
    — Direct data exchangeNo
    — IRTNo
    — PROFIenergyYes
    — Prioritized startupNo
    — Number of connectable IO Devices, max.32; In total, up to 512 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
    — Number of connectable IO Devices for RT, max.32
    — of which in line, max.32
    — Number of IO Devices that can be simultaneously activated/deactivated, max.8; in total across all interfaces
    — Number of IO Devices per tool, max.8
    — Updating timesThe minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
    Update time for RT
    — for send cycle of 1 ms1 ms to 512 ms
    PROFINET IO Device
    Services
    — PG/OP communicationYes
    — Isochronous modeNo
    — IRTNo
    — PROFIenergyYes; per user program
    — Prioritized startupNo
    — Shared deviceYes
    — Number of IO Controllers with shared device, max.4
    — Asset management recordYes; per user program
    Interface types
    RJ 45 (Ethernet)
    ● 100 MbpsYes
    ● AutonegotiationYes
    ● AutocrossingYes
    ● Industrial Ethernet status LEDYes
    Protocols
    PROFIsafeYes
    Number of connections
    ● Number of connections, max.128; Via integrated interfaces of the CPU
    ● Number of connections reserved for ES/HMI/web10
    ● Number of connections via integrated interfaces128
    ● Number of S7 routing paths16
    Redundancy mode
    Media redundancy
    — MRPYes; as MRP redundancy manager and/or MRP client
    — MRPDYes; Requirement: IRT
    — Switchover time on line break, typ.200 ms; For MRP, bumpless for MRPD
    — Number of stations in the ring, max.50
    SIMATIC communication
    ● S7 routingYes
    ● S7 communication, as serverYes
    ● S7 communication, as clientYes
    ● User data per job, max.See online help (S7 communication, user data size)
    Open IE communication
    ● TCP/IPYes
    — Data length, max.64 kbyte
    — several passive connections per port, supportedYes
    ● ISO-on-TCP (RFC1006)Yes
    — Data length, max.64 kbyte
    ● UDPYes
    — Data length, max.2 kbyte; 1 472 bytes for UDP broadcast
    — UDP multicastYes; Max. 5 multicast circuits
    ● DHCPNo
    ● SNMPYes
    ● DCPYes
    ● LLDPYes
    Web server
    ● HTTPYes; Standard and user pages
    ● HTTPSYes; Standard and user pages
    OPC UA
    ● Runtime license requiredYes; "Small" license required
    ● OPC UA ClientYes
    — Application authenticationYes
    — Security policiesAvailable security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256
    — User authentication"anonymous" or by user name & password
    — Number of connections, max.4
    — Number of nodes of the client interfaces, recommended max.1 000
    — Number of elements for one call of OPC_UA_NodeGetHandleList/OPC_UA_ReadList/OPC_UA_WriteList, max.300
    — Number of elements for one call of OPC_UA_NameSpaceGetIndexList, max.20
    — Number of elements for one call of OPC_UA_MethodGetHandleList, max.100
    — Number of simultaneous calls of the client instructions for session management, per connection, max.1
    — Number of simultaneous calls of the client instructions for data access, per connection, max.5
    — Number of registerable nodes, max.5 000
    — Number of registerable method calls of OPC_UA_MethodCall, max.100
    — Number of inputs/outputs when calling OPC_UA_MethodCall, max.20
    ● OPC UA ServerYes; Data access (read, write, subscribe), method call, custom address space
    — Application authenticationYes
    — Security policiesAvailable security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256
    — User authentication"anonymous" or by user name & password
    — Number of sessions, max.32
    — Number of accessible variables, max.50 000
    — Number of registerable nodes, max.10 000
    — Number of subscriptions per session, max.20
    — Sampling interval, min.100 ms
    — Publishing interval, min.500 ms
    — Number of server methods, max.20
    — Number of inputs/outputs per server method, max.20
    — Number of monitored items, recommended max.1 000; for 1 s sampling interval and 1 s send interval
    — Number of server interfaces, max.10
    — Number of nodes for user-defined server interfaces, max.1 000