Sign In | Join Free | My burrillandco.com
Home > IFM Vacuum Sensors >

OEM IFM PV7002 Pressure Switch Sensor Distributors PV-100-SEG14-UFRVG/US/ /

    Buy cheap OEM IFM PV7002 Pressure Switch Sensor Distributors PV-100-SEG14-UFRVG/US/ / from wholesalers
     
    Buy cheap OEM IFM PV7002 Pressure Switch Sensor Distributors PV-100-SEG14-UFRVG/US/ / from wholesalers
    • Buy cheap OEM IFM PV7002 Pressure Switch Sensor Distributors PV-100-SEG14-UFRVG/US/ / from wholesalers
    • Buy cheap OEM IFM PV7002 Pressure Switch Sensor Distributors PV-100-SEG14-UFRVG/US/ / from wholesalers

    OEM IFM PV7002 Pressure Switch Sensor Distributors PV-100-SEG14-UFRVG/US/ /

    Ask Lasest Price
    Brand Name : IFM
    Model Number : PV7002
    Certification : CE
    Price : USD
    Payment Terms : L/C, T/T
    Supply Ability : 100
    Delivery Time : 10-12Days
    • Product Details
    • Company Profile

    OEM IFM PV7002 Pressure Switch Sensor Distributors PV-100-SEG14-UFRVG/US/ /

    IFM Pressure switch with IO-Link PV7002 PV-100-SEG14-UFRVG/US/ /

    The IFM PV7002 PV-100-SEG14-UFRVG/US/P is a pressure switch with IO-Link functionality. Here's some information about the pressure switch:

    1. Model: PV7002 PV-100-SEG14-UFRVG/US/P
    2. Manufacturer: IFM Electronic GmbH
    3. Function: The pressure switch is designed to monitor and control the pressure of a fluid in a system or process. It allows for the detection of specific pressure thresholds and can trigger actions or signals based on those thresholds.
    4. Pressure Measurement Range: The specific pressure measurement range of the switch depends on the model variant. Unfortunately, the provided model number does not contain information about the pressure range. It's recommended to refer to the product documentation or datasheet for the exact pressure measurement range of this particular model.
    5. IO-Link Functionality: The pressure switch is equipped with IO-Link, which is a communication protocol that allows for bi-directional communication between the switch and a controller or other devices. IO-Link enables enhanced configuration, monitoring, and diagnostics capabilities for the pressure switch.
    6. Electrical Connection: The switch supports a specific electrical connection type, indicated by the "/US/P" in the model name. The "/US" may represent a connector or electrical connection type compatible with the US market, while the "/P" could indicate additional details regarding the electrical connection or functionality. For precise information, it's best to consult the product documentation or datasheet.
    7. Housing Type: The pressure switch is likely housed in a robust enclosure suitable for industrial environments. The specific details of the housing type or design are not evident from the provided model number.

    For detailed specifications, installation guidelines, and compatibility information for the IFM PV7002 PV-100-SEG14-UFRVG/US/P pressure switch with IO-Link functionality, it is recommended to consult the official documentation provided by IFM Electronic GmbH or contact their technical support. They will be able to provide you with accurate and up-to-date information based on your specific requirements and the latest product information available.

    Product characteristics

    Number of inputs and outputsNumber of digital outputs: 2
    Measuring range
    0...100 bar0...1450 psi0...10 MPa

    Process connectionthreaded connection G 1/4 external thread (DIN EN ISO 1179-2); internal thread:M5

    Application

    Measuring elementmetallic thin film cell
    Applicationfor industrial applications
    Medialiquids and gases
    Medium temperature [°C]-40...90
    Min. bursting pressure
    1000 bar14500 psi100 MPa

    Pressure rating
    250 bar3625 psi25 MPa

    Note on pressure rating
    static

    Vacuum resistance [mbar]-1000
    Type of pressurerelative pressure

    Electrical data

    Operating voltage [V]18...30 DC
    Current consumption [mA]< 15
    Min. insulation resistance [MΩ]100; (500 V DC)
    Protection classIII
    Reverse polarity protectionyes
    Power-on delay time [s]< 0.3

    Inputs / outputs

    Number of inputs and outputsNumber of digital outputs: 2

    Outputs

    Total number of outputs2
    Output signalswitching signal; IO-Link; (configurable)
    Electrical designPNP/NPN
    Number of digital outputs2
    Output functionnormally open / normally closed; (parameterisable)
    Max. voltage drop switching output DC [V]2
    Permanent current rating of switching output DC [mA]100
    Switching frequency DC [Hz]< 170
    Short-circuit protectionyes
    Type of short-circuit protectionpulsed
    Overload protectionyes

    Measuring/setting range

    Measuring range
    0...100 bar0...1450 psi0...10 MPa

    Set point SP
    1...100 bar15...1450 psi0.1...10 MPa

    Reset point rP
    0.5...99.5 bar7...1443 psi0.05...9.95 MPa

    In steps of
    0.05 bar1 psi0.005 MPa

    Factory setting
    SP1 = 25 barrP1 = 23 barou1 = Hno;
    SP2 = 75 barrP2 = 73 barou2 = Hno;
    dS1/dS2 = 0 msdr1/dr2 = 0 ms
    coF = 0 %P-n = PnPdAP= 60 ms

    Accuracy / deviations

    Switch point accuracy [% of the span]< ± 0,5 (nach DIN EN 61298-2)
    Repeatability [% of the span]< ± 0,05; (with temperature fluctuations < 10 K)
    Characteristics deviation [% of the span]< ± 0,5; (linearity incl. hysteresis and repeatability, limit value setting to DIN EN IEC 62828-1)
    Linearity deviation [% of the span]< ± 0,1 (BFSL) / < ± 0,2 (LS)
    Hysteresis deviation [% of the span]< ± 0,2
    Long-term stability [% of the span]< ± 0,1; (per 6 months)
    Temperature coefficient zero point [% of the span / 10 K]< 0,1 (-25...90 °C) / < 0,2 (-40...-25 °C)
    Temperature coefficient span [% of the span / 10 K]< 0,1 (-25...90 °C) / < 0,2 (-40...-25 °C)

    Response times

    Response time [ms]< 3

    Software / programming

    Parameter setting optionshysteresis / window; normally open / normally closed; switching logic; switch-on/switch-off delay; Damping

    Interfaces

    Communication interfaceIO-Link
    Transmission typeCOM2 (38,4 kBaud)
    IO-Link revision1.1
    SDCI standardIEC 61131-9
    ProfilesSmart Sensor: Process Data Variable; Device Identification, Device Diagnosis
    SIO modeyes
    Required master port typeA
    Process data analogue2
    Process data binary2
    Min. process cycle time [ms]5
    Supported DeviceIDs
    Type of operationDeviceID
    default710


    OEM IFM PV7002 Pressure Switch Sensor Distributors PV-100-SEG14-UFRVG/US/ /OEM IFM PV7002 Pressure Switch Sensor Distributors PV-100-SEG14-UFRVG/US/ /

    Quality OEM IFM PV7002 Pressure Switch Sensor Distributors PV-100-SEG14-UFRVG/US/ / for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Voboal Industrial Automation Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)