    Brand Name : SIEMENS
    Model Number : 6ES7412-2XJ05-0AB0
    Certification : CE
    Price : USD
    Payment Terms : L/C, T/T
    Supply Ability : 10PS
    Delivery Time : 5-10DAYS
    • Product Details
    • Company Profile

    SIEMENS SIMATIC PLC S7-400 6ES7412-2XJ05-0AB0 CPU 412-2 Central processing unit with

    I apologize for the confusion earlier. Here is the corrected information for the SIEMENS SIMATIC PLC S7-400 6ES7412-2XJ05-0AB0 CPU 412-2:

    Product Name: SIEMENS SIMATIC PLC S7-400 6ES7 412-2XJ05-0AB0 CPU 412-2

    Introduction:
    The SIEMENS SIMATIC PLC S7-400 6ES7 412-2XJ05-0AB0 CPU 412-2 is a central processing unit (CPU) designed for the SIEMENS SIMATIC S7-400 series programmable logic controllers (PLCs). It provides high-performance control and communication capabilities for large and complex automation applications.

    Origin: Germany

    Product Specifications:
    - Product Name: SIEMENS SIMATIC PLC S7-400 6ES7 412-2XJ05-0AB0 CPU 412-2
    - CPU Type: 412-2
    - Compatibility: SIEMENS SIMATIC S7-400 series
    - Number of Digital Inputs: Varies depending on configuration
    - Number of Digital Outputs: Varies depending on configuration
    - Number of Analog Inputs: Varies depending on configuration
    - Number of Analog Outputs: Varies depending on configuration
    - Communication Ports: Multiple communication interfaces (e.g., Ethernet, PROFIBUS, MPI)
    - Memory: Varies depending on configuration
    - Operating Temperature: 0 to 60°C
    - Dimensions (W x H x D): Varies depending on the module
    - Weight: Varies depending on the module

    Product Features:
    - Central processing unit (CPU) for large and complex automation applications
    - Compatible with the SIEMENS SIMATIC S7-400 series
    - Supports a wide range of digital and analog inputs and outputs
    - Multiple communication interfaces for seamless integration into industrial networks
    - Flexible memory configuration to accommodate specific application requirements
    - Robust construction and reliable performance for demanding industrial environments
    - Easy programming and configuration using the STEP 7 programming software

    Functionality:
    - The SIMATIC PLC S7-400 6ES7 412-2XJ05-0AB0 CPU 412-2 is designed to provide high-performance control and communication capabilities for large and complex automation applications.
    - It is compatible with the SIEMENS SIMATIC S7-400 series, allowing for seamless integration with other modules and components.
    - The CPU supports a wide range of digital and analog inputs and outputs, providing flexibility for various automation requirements.
    - Multiple communication interfaces (such as Ethernet, PROFIBUS, and MPI) enable easy connectivity to other devices and networks.
    - The memory configuration can be customized to accommodate specific application requirements.
    - With its robust construction and reliable performance, the CPU is suitable for demanding industrial environments.
    - Programming and configuration can be done using the STEP 7 programming software, which offers a user-friendly interface for efficient development and maintenance.

    Please note that for more detailed technical specifications and information, it is recommended to refer to the official documentation or contact Siemens directly.

    SIEMENS SIMATIC PLC S7-400 6ES7412-2XJ05-0AB0 CPU 412-2 Central processing unit withSIEMENS SIMATIC PLC S7-400 6ES7412-2XJ05-0AB0 CPU 412-2 Central processing unit withSIEMENS SIMATIC PLC S7-400 6ES7412-2XJ05-0AB0 CPU 412-2 Central processing unit with

    Replacement part ********* SIMATIC S7-400, CPU 412-2 Central processing unit with: work memory 512 KB, (256 KB code, 256 KB of data), 1st interface MPI/DP 12 Mbit/s, 2nd interface PROFIBUS DP
    General information
    Product type designation CPU 412-2
    HW functional status 03
    Firmware version V5.3
    Product function
    ● Isochronous mode Yes; For PROFIBUS only
    Engineering with
    ● Programming package STEP 7 V5.3 SP2 or higher with HW update
    CiR - Configuration in RUN
    CiR synchronization time, basic load 100 ms
    CiR synchronization time, time per I/O byte 30 µs
    Supply voltage
    Rated value (DC) Power supply via system power supply
    Input current
    from backplane bus 5 V DC, typ. 0.9 A
    from backplane bus 5 V DC, max. 1.1 A
    from backplane bus 24 V DC, max. 300 mA; 150 mA per DP interface
    from interface 5 V DC, max. 90 mA; At each DP interface
    Power loss
    Power loss, typ. 4.5 W
    Power loss, max. 5 W
    Memory
    Type of memory RAM
    Work memory
    ● integrated 512 kbyte
    ● integrated (for program) 256 kbyte
    ● integrated (for data) 256 kbyte
    ● expandable No
    Load memory
    ● expandable FEPROM Yes; with Memory Card (FLASH)
    ● expandable FEPROM, max. 64 Mbyte
    ● integrated RAM, max. 512 kbyte
    ● expandable RAM Yes; with Memory Card (RAM)
    ● expandable RAM, max. 64 Mbyte
    Backup
    ● present Yes
    ● with battery Yes; all data
    ● without battery No
    Battery
    Backup battery
    ● Backup current, typ. 125 µA; up to 40 °C
    ● Backup current, max. 550 µA
    ● Backup time, max. See reference manual, module data, Chapter 3.3
    ● Feeding of external backup voltage to CPU 5 V DC to 15 V DC
    CPU processing times
    for bit operations, typ. 75 ns
    for word operations, typ. 75 ns
    for fixed point arithmetic, typ. 75 ns
    for floating point arithmetic, typ. 225 ns
    CPU-blocks
    DB
    ● Number, max. 3 000; Number range: 1 to 16000
    ● Size, max. 64 kbyte
    FB
    ● Number, max. 1 500; Number range: 0 to 7999
    ● Size, max. 64 kbyte
    FC
    ● Number, max. 1 500; Number range: 0 to 7999
    ● Size, max. 64 kbyte
    OB
    ● Number, max. see instruction list
    ● Size, max. 64 kbyte
    ● Number of free cycle OBs 1; OB 1
    ● Number of time alarm OBs 2; OB 10, 11
    ● Number of delay alarm OBs 2; OB 20, 21
    ● Number of cyclic interrupt OBs 2; OB 32, 35 (shortest cycle that can be set = 500 µs)
    ● Number of process alarm OBs 2; OB 40, 41
    ● Number of DPV1 alarm OBs 3; OB 55-57
    ● Number of isochronous mode OBs 2; OB 61-62
    ● Number of multicomputing OBs 1; OB 60
    ● Number of background OBs 1; OB 90
    ● Number of startup OBs 3; OB 100-102
    ● Number of asynchronous error OBs 9; OB 80-88
    ● Number of synchronous error OBs 2; OB 121, 122
    Nesting depth
    ● per priority class 24
    ● additional within an error OB 1
    Counters, timers and their retentivity
    S7 counter
    ● Number 2 048
    Retentivity
    — adjustable Yes
    — preset Z 0 to Z 7
    Counting range
    — lower limit 0
    — upper limit 999
    IEC counter
    ● present Yes
    ● Type SFB
    ● Number Unlimited (limited only by RAM capacity)
    S7 times
    ● Number 2 048
    Retentivity
    — adjustable Yes
    — preset No times retentive
    Time range
    — lower limit 10 ms
    — upper limit 9 990 s
    IEC timer
    ● present Yes
    ● Type SFB
    ● Number Unlimited (limited only by RAM capacity)
    Data areas and their retentivity
    Retentive data area (incl. timers, counters, flags), max. Total working and load memory (with backup battery)
    Flag
    ● Size, max. 4 kbyte; Size of bit memory address area
    ● Retentivity available Yes
    ● Retentivity preset MB 0 to MB 15
    ● Number of clock memories 8; in 1 memory byte
    Local data
    ● adjustable, max. 8 kbyte
    ● preset 4 kbyte
    Address area
    I/O address area
    ● Inputs 4 kbyte
    ● Outputs 4 kbyte
    Process image
    ● Inputs, adjustable 4 kbyte
    ● Outputs, adjustable 4 kbyte
    ● Inputs, default 128 byte
    ● Outputs, default 128 byte
    ● consistent data, max. 244 byte
    ● Access to consistent data in process image Yes
    Subprocess images
    ● Number of subprocess images, max. 15
    Digital channels
    ● Inputs 32 768
    — of which central 32 768
    ● Outputs 32 768
    — of which central 32 768
    Analog channels
    ● Inputs 2 048
    — of which central 2 048
    ● Outputs 2 048
    — of which central 2 048
    Hardware configuration
    Integrated power supply No
    Number of expansion units, max. 21
    connectable OPs 31
    Multicomputing Yes; 4 CPUs max. (with UR1 or UR2)
    Interface modules
    ● Number of connectable IMs (total), max. 6
    ● Number of connectable IM 460s, max. 6
    ● Number of connectable IM 463s, max. 4; IM 463-2
    Number of DP masters
    ● integrated 2
    ● via CP 10; CP 443-5 Extended
    ● via IM 467 4
    ● Mixed mode IM + CP permitted No; IM 467 not suitable for use with CP 443-5 Ext. and CP 443-1 EX4x, EX20, GX20 (in PROFINET IO mode)
    ● via interface module 0
    ● Number of pluggable S5 modules (via adapter capsule in central device), max. 6
    Number of IO Controllers
    ● integrated 0
    ● via CP 4; No mixed operation of CP443-1 EX40 and CP443-1 EX 41/EX20/GX20, max. 4 in central controller
    Number of operable FMs and CPs (recommended)
    ● FM Limited by number of slots and number of connections
    ● CP, PtP CP 440: Limited by number of slots; CP 441: Limited by number of slots and number of connections
    ● PROFIBUS and Ethernet CPs 14; Of which 10 CPs max. or IMs as DP master, 4 PROFINET controller maximum
    Slots
    ● required slots 1
    Time of day
    Clock
    ● Hardware clock (real-time) Yes
    ● retentive and synchronizable Yes
    ● Resolution 1 ms
    ● Deviation per day (buffered), max. 1.7 s; Power off
    ● Deviation per day (unbuffered), max. 8.6 s; For power On
    Operating hours counter
    ● Number 16
    ● Number/Number range 0 to 15
    ● Range of values SFCs 2, 3 and 4: 0 to 32767 hours SFC 101: 0 to 2^31 - 1 hours
    ● Granularity 1 h
    ● retentive Yes
    Clock synchronization
    ● supported Yes
    ● to MPI, master Yes
    ● to MPI, slave Yes
    ● to DP, master Yes
    ● to DP, slave Yes
    ● in AS, master Yes
    ● in AS, slave Yes
    ● on Ethernet via NTP No; Via CP
    Time difference in system when synchronizing via
    ● MPI, max. 200 ms
    Interfaces
    Interfaces/bus type 1 x MPI/PROFIBUS DP, 1 x PROFIBUS DP
    Number of RS 485 interfaces 2; Combined MPI / PROFIBUS DP and PROFIBUS DP
    Optical interface No
    1. Interface
    Interface type MPI/PROFIBUS DP
    Isolated Yes
    Interface types
    ● RS 485 Yes
    ● Output current of the interface, max. 150 mA
    Protocols
    ● MPI Yes
    ● PROFIBUS DP master Yes
    ● PROFIBUS DP slave Yes
    MPI
    ● Number of connections 32; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1
    ● Transmission rate, max. 12 Mbit/s
    Services
    — PG/OP communication Yes
    — Routing Yes
    — Global data communication Yes
    — S7 basic communication Yes
    — S7 communication Yes
    — S7 communication, as client Yes
    — S7 communication, as server Yes
    PROFIBUS DP master
    ● Number of connections, max. 16; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1
    ● Transmission rate, max. 12 Mbit/s
    ● Number of DP slaves, max. 32
    Services
    — PG/OP communication Yes
    — Routing Yes; S7 routing
    — Global data communication No
    — S7 basic communication Yes
    — S7 communication Yes
    — S7 communication, as client Yes
    — S7 communication, as server Yes
    — Equidistance Yes
    — Isochronous mode Yes
    — SYNC/FREEZE Yes
    — Activation/deactivation of DP slaves Yes
    — Direct data exchange (slave-to-slave communication) Yes
    — DPV1 Yes
    Address area
    — Inputs, max. 2 kbyte
    — Outputs, max. 2 kbyte
    User data per DP slave
    — User data per DP slave, max. 244 byte
    — Inputs, max. 244 byte
    — Outputs, max. 244 byte
    — Slots, max. 244
    — per slot, max. 128 byte
    PROFIBUS DP slave
    ● Number of connections 16
    ● GSD file http://support.automation.siemens.com/WW/view/en/113652
    ● Transmission rate, max. 12 Mbit/s
    ● automatic baud rate search No
    ● Address area, max. 32; Virtual slots
    ● User data per address area, max. 32 byte
    — of which consistent, max. 32 byte
    Services
    — PG/OP communication Yes; with interface active
    — Routing Yes; with interface active
    — Global data communication No
    — S7 basic communication No
    — S7 communication Yes
    — S7 communication, as client Yes
    — S7 communication, as server Yes
    — Direct data exchange (slave-to-slave communication) No
    — DPV1 No
    Transfer memory
    — Inputs 244 byte
    — Outputs 244 byte
    2. Interface
    Interface type PROFIBUS DP
    Isolated Yes
    Interface types
    ● RS 485 Yes
    ● Output current of the interface, max. 150 mA
    Protocols
    ● PROFIBUS DP master Yes
    ● PROFIBUS DP slave Yes
    PROFIBUS DP master
    ● Number of connections, max. 16
    ● Transmission rate, max. 12 Mbit/s
    ● Number of DP slaves, max. 64
    Services
    — PG/OP communication Yes
    — Routing Yes; S7 routing
    — Global data communication No
    — S7 basic communication Yes
    — S7 communication Yes
    — S7 communication, as client Yes
    — S7 communication, as server Yes
    — Equidistance Yes
    — Isochronous mode Yes
    — SYNC/FREEZE Yes
    — Activation/deactivation of DP slaves Yes
    — Direct data exchange (slave-to-slave communication) Yes
    — DPV1 Yes
    Address area
    — Inputs, max. 4 kbyte
    — Outputs, max. 4 kbyte
    User data per DP slave
    — User data per DP slave, max. 244 byte
    — Inputs, max. 244 byte
    — Outputs, max. 244 byte
    — Slots, max. 244
    — per slot, max. 128 byte
    PROFIBUS DP slave
    ● Number of connections 16
    ● GSD file http://support.automation.siemens.com/WW/view/en/113652
    ● Transmission rate, max. 12 Mbit/s
    ● Address area, max. 32
    ● User data per address area, max. 32 byte
    — of which consistent, max. 32 byte
    Services
    — Routing Yes
    Transfer memory
    — Inputs 244 byte
    — Outputs 244 byte
    Protocols
    SIMATIC communication
    ● S7 routing Yes
    Open IE communication
    ● ISO-on-TCP (RFC1006) Via CP 443-1 and loadable FB
    — Data length, max. 1 452 bytes via CP 443-1 Adv.
    Web server
    ● supported No
    Isochronous mode
    Equidistance Yes
    Number of DP masters with isochronous mode 2
    User data per isochronous slave, max. 244 byte
    shortest clock pulse 1.5 ms; 0.5 ms without use of SFC 126, 127
    max. cycle 32 ms
    communication functions / header
    PG/OP communication Yes
    ● Number of connectable OPs without message processing 31
    ● Number of connectable OPs with message processing 31; When using Alarm_S/SQ and Alarm_D/DQ
    Data record routing Yes
    Global data communication
    ● supported Yes
    ● Number of GD loops, max. 8
    ● Number of GD packets, transmitter, max. 8
    ● Number of GD packets, receiver, max. 16
    ● Size of GD packets, max. 54 byte
    ● Size of GD packet (of which consistent), max. 1 variable
    S7 basic communication
    ● communication function / S7 basic communication Yes
    ● User data per job, max. 76 byte
    ● User data per job (of which consistent), max. 1 variable
    S7 communication
    ● supported Yes
    ● as server Yes
    ● as client Yes
    ● User data per job, max. 64 kbyte
    ● User data per job (of which consistent), max. 462 byte; 1 variable
    S5 compatible communication
    ● supported Yes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5
    ● User data per job, max. 8 kbyte
    ● User data per job (of which consistent), max. 240 byte
    ● Number of simultaneous AG-SEND/AG-RECV orders per CPU, max. 24/24
    Standard communication (FMS)
    ● supported Yes; Via CP and loadable FB
    Number of connections
    ● overall 32
    ● usable for PG communication 31
    — reserved for PG communication 1
    — adjustable for PG communication, max. 0
    ● usable for OP communication 31
    — reserved for OP communication 1
    — adjustable for OP communication, max. 0
    ● usable for S7 basic communication 30
    — reserved for S7 basic communication 0
    — adjustable for S7 basic communication, max. 0
    ● usable for S7 communication 30
    — reserved for S7 communication 0
    — adjustable for S7 communication, max. 0
    ● usable for routing 15
    — reserved for routing 0
    — adjustable for routing, max. 0
    S7 message functions
    Number of login stations for message functions, max. 31; Max. 31 with Alarm_S/SQ and Alarm_D/DQ (OPs); max. 8 with Alarm_8 and Alarm_P (e.g. WinCC)
    Symbol-related messages Yes
    SCAN procedure Yes
    Program alarms Yes
    Process diagnostic messages Yes
    simultaneously active Alarm-S blocks, max. 250; Simultaneously active alarm_S/SQ blocks or alarm_D/DQ blocks
    Alarm 8-blocks Yes
    ● Number of instances for alarm 8 and S7 communication blocks, max. 300
    ● preset, max. 150
    Process control messages Yes
    Number of archives that can log on simultaneously (SFB 37 AR_SEND) 4
    Number of messages
    ● overall, max. 256
    ● in 100 ms grid, max. 0
    ● in 500 ms grid, max. 256
    ● in 1000 ms grid, max. 256
    Number of additional values
    ● with 100 ms grid, max. 0
    ● with 500, 1000 ms grid, max. 1
    Test commissioning functions
    Status block Yes; Up to 2 simultaneously
    Single step Yes
    Number of breakpoints 4
    Status/control
    ● Status/control variable Yes; Up to 16 variable tables
    ● Variables Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
    ● Number of variables, max. 70; Status/control
    Forcing
    ● Forcing Yes
    ● Forcing, variables Inputs, outputs, bit memories, peripheral inputs, peripheral outputs
    ● Number of variables, max. 64
    Diagnostic buffer
    ● present Yes
    ● Number of entries, max. 400
    — adjustable Yes
    — preset 120
    Service data
    ● can be read out Yes
    Standards, approvals, certificates
    CE mark Yes
    CSA approval Yes
    UL approval Yes
    cULus Yes
    FM approval Yes
    RCM (formerly C-TICK) Yes
    KC approval Yes
    EAC (formerly Gost-R) Yes
    Use in hazardous areas
    ● ATEX ATEX II 3G Ex nA IIC T4 Gc
    Ambient conditions
    Ambient temperature during operation
    ● min. 0 °C
    ● max. 60 °C
    configuration / header
    Configuration software
    ● STEP 7 Yes
    configuration / programming / header
    ● Command set see instruction list
    ● Nesting levels 7
    ● Access to consistent data in process image Yes
    ● System functions (SFC) see instruction list
    ● System function blocks (SFB) see instruction list
    Programming language
    — LAD Yes
    — FBD Yes
    — STL Yes
    — SCL Yes
    — CFC Yes
    — GRAPH Yes
    — HiGraph® Yes
    configuration / programming / number of simultaneously active SFC / header
    — DPSYC_FR 2; SFC 11; per interface
    — D_ACT_DP 8; SFC 12; per interface
    — RD_REC 8; SFC 59; per interface
    — WR_REC 8; SFC 58; per interface
    — WR_PARM 8; SFC 55; per interface
    — PARM_MOD 1; SFC 57; per interface
    — WR_DPARM 2; SFC 56; per interface
    — DPNRM_DG 8; SFC 13; per interface
    — RDSYSST 8
    — DP_TOPOL 1; SFC 103; per interface
    configuration / programming / number of simultaneously active SFB / header
    — RDREC 8; SFB 52; per interface, but not more than 32 across all external interfaces
    — WRREC 8; SFB 53; per interface, but not more than 32 across all external interfaces
    Know-how protection
    ● User program protection/password protection Yes
    Dimensions
    Width 25 mm
    Height 290 mm
    Depth 219 mm
    Weights
    Weight, approx. 700 g