Sign In | Join Free | My burrillandco.com
Home > PLC SIMATIC S7-1500 >

SIEMENS 6ES7511-1FK02-0AB0 WITH 2 PORT SWITCH, 60 NS BIT-PERFORMANCE, SIMATIC MEMORY CARD NECESSARY

    Buy cheap SIEMENS 6ES7511-1FK02-0AB0 WITH 2 PORT SWITCH, 60 NS BIT-PERFORMANCE, SIMATIC MEMORY CARD NECESSARY from wholesalers
     
    Buy cheap SIEMENS 6ES7511-1FK02-0AB0 WITH 2 PORT SWITCH, 60 NS BIT-PERFORMANCE, SIMATIC MEMORY CARD NECESSARY from wholesalers
    • Buy cheap SIEMENS 6ES7511-1FK02-0AB0 WITH 2 PORT SWITCH, 60 NS BIT-PERFORMANCE, SIMATIC MEMORY CARD NECESSARY from wholesalers

    SIEMENS 6ES7511-1FK02-0AB0 WITH 2 PORT SWITCH, 60 NS BIT-PERFORMANCE, SIMATIC MEMORY CARD NECESSARY

    Ask Lasest Price
    Brand Name : SIEMENS
    Model Number : 6ES7511-1FK02-0AB0
    Certification : CE
    Price : USD
    Payment Terms : L/C, T/T
    Supply Ability : 100
    Delivery Time : 10-12Days
    • Product Details
    • Company Profile

    SIEMENS 6ES7511-1FK02-0AB0 WITH 2 PORT SWITCH, 60 NS BIT-PERFORMANCE, SIMATIC MEMORY CARD NECESSARY

    SIEMENS 6ES7511-1FK02-0AB0 WITH 2 PORT SWITCH, 60 NS BIT-PERFORMANCE, SIMATIC MEMORY CARD NECESSARY

    The SIEMENS 6ES7511-1FK02-0AB0 is a central processing unit (CPU) that is part of the SIMATIC S7-1500 automation system. Here are the key details about this CPU:

    PROFINET IRT with 2-Port Switch:
    - This CPU has a built-in PROFINET interface with an integrated 2-port switch.
    - The PROFINET interface supports the PROFINET IRT (Isochronous Real-Time) communication protocol, which enables highly synchronized and deterministic data exchange.
    - The 2-port switch allows the CPU to be connected directly to other PROFINET devices without requiring an external switch.

    Fast 60 ns Bit Performance:
    - This CPU has an extremely fast bit performance of 60 nanoseconds per bit operation.
    - The 60 ns bit performance provides very responsive and precise control capabilities for industrial automation applications.

    SIMATIC Memory Card Required:
    - Like other SIMATIC S7-1500 CPUs, this model requires a SIMATIC memory card to be inserted for operation.
    - The memory card provides storage for the user program, configuration data, and other runtime information.

    Other Features:
    - Work Memory: 1 MB for program and 5 MB for data
    - Part of the modular SIMATIC S7-1500 system
    - Programmed using the STEP 7 engineering software

    The key distinguishing features of this CPU model are the integrated PROFINET IRT interface with a 2-port switch and the extremely fast 60 ns bit performance.

    Compared to the previous 6ES7511-1FK01-0AB0 model, this 6ES7511-1FK02-0AB0 version has increased work memory capacities (1 MB program, 5 MB data), while maintaining the same 60 ns bit performance.

    These capabilities make the CPU 1511-1 PN an excellent choice for applications that require highly synchronized and deterministic industrial Ethernet communication, combined with extremely fast and responsive control performance.

    The 2-port switch provides convenient connectivity options, while the 60 ns bit performance delivers remarkably precise and efficient control for the most demanding industrial automation tasks.

    Overall, the 6ES7511-1FK02-0AB0 is a high-performance CPU within the SIMATIC S7-1500 portfolio, designed for advanced industrial automation applications that need the ultimate in communication performance and control responsiveness, with additional program and data storage capacity.

    General information
    Product type designationCPU 1511F-1 PN
    HW functional statusFS03
    Firmware versionV2.8
    Product function
    ● I&M dataYes; I&M0 to I&M3
    ● Isochronous modeYes; Distributed and central; with minimum OB 6x cycle of 625 µs (distributed) and 1 ms (central)
    Engineering with
    ● STEP 7 TIA Portal configurable/integrated from versionV16 (FW V2.8) / V15 (FW V2.5) or higher; with older TIA Portal versions configurable as 6ES7511-1FK01-0AB0
    Configuration control
    via datasetYes
    Display
    Screen diagonal [cm]3.45 cm
    Control elements
    Number of keys8
    Mode buttons2
    Supply voltage
    permissible range, lower limit (DC)19.2 V
    permissible range, upper limit (DC)28.8 V
    Reverse polarity protectionYes
    Mains buffering
    ● Mains/voltage failure stored energy time5 ms
    Input current
    Current consumption (rated value)0.7 A
    Current consumption, max.0.95 A
    Inrush current, max.1.9 A; Rated value
    I²t0.02 A²·s
    Power
    Infeed power to the backplane bus10 W
    Power consumption from the backplane bus (balanced)5.5 W
    Power loss
    Power loss, typ.5.7 W
    Memory
    Number of slots for SIMATIC memory card1
    SIMATIC memory card requiredYes
    Work memory
    ● integrated (for program)225 kbyte
    ● integrated (for data)1 Mbyte
    Load memory
    ● Plug-in (SIMATIC Memory Card), max.32 Gbyte
    Backup
    ● maintenance-freeYes
    CPU processing times
    for bit operations, typ.60 ns
    for word operations, typ.72 ns
    for fixed point arithmetic, typ.96 ns
    for floating point arithmetic, typ.384 ns
    CPU-blocks
    Number of elements (total)2 000; Blocks (OB, FB, FC, DB) and UDTs
    DB
    ● Number range1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999
    ● Size, max.1 Mbyte; For DBs with absolute addressing, the max. size is 64 KB
    FB
    ● Number range0 ... 65 535
    ● Size, max.150 kbyte
    FC
    ● Number range0 ... 65 535
    ● Size, max.150 kbyte
    OB
    ● Size, max.150 kbyte
    ● Number of free cycle OBs100
    ● Number of time alarm OBs20
    ● Number of delay alarm OBs20
    ● Number of cyclic interrupt OBs20; With minimum OB 3x cycle of 500 µs
    ● Number of process alarm OBs50
    ● Number of DPV1 alarm OBs3
    ● Number of isochronous mode OBs2
    ● Number of technology synchronous alarm OBs2
    ● Number of startup OBs100
    ● Number of asynchronous error OBs4
    ● Number of synchronous error OBs2
    ● Number of diagnostic alarm OBs1
    Nesting depth
    ● per priority class24; Up to 8 possible for F-blocks
    Counters, timers and their retentivity
    S7 counter
    ● Number2 048
    Retentivity
    — adjustableYes
    IEC counter
    ● NumberAny (only limited by the main memory)
    Retentivity
    — adjustableYes
    S7 times
    ● Number2 048
    Retentivity
    — adjustableYes
    IEC timer
    ● NumberAny (only limited by the main memory)
    Retentivity
    — adjustableYes
    Data areas and their retentivity
    Retentive data area (incl. timers, counters, flags), max.128 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 88 KB
    Extended retentive data area (incl. timers, counters, flags), max.1 Mbyte; When using PS 6 0W 24/48/60 V DC HF
    Flag
    ● Size, max.16 kbyte
    ● Number of clock memories8; 8 clock memory bit, grouped into one clock memory byte
    Data blocks
    ● Retentivity adjustableYes
    ● Retentivity presetNo
    Local data
    ● per priority class, max.64 kbyte; max. 16 KB per block
    Address area
    Number of IO modules1 024; max. number of modules / submodules
    I/O address area
    ● Inputs32 kbyte; All inputs are in the process image
    ● Outputs32 kbyte; All outputs are in the process image
    per integrated IO subsystem
    — Inputs (volume)8 kbyte
    — Outputs (volume)8 kbyte
    per CM/CP
    — Inputs (volume)8 kbyte
    — Outputs (volume)8 kbyte
    Subprocess images
    ● Number of subprocess images, max.32
    Hardware configuration
    Number of distributed IO systems32; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS communication modules, but also by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link)
    Number of DP masters
    ● Via CM4; A maximum of 4 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total
    Number of IO Controllers
    ● integrated1
    ● Via CM4; A maximum of 4 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total
    Rack
    ● Modules per rack, max.32; CPU + 31 modules
    PtP CM
    ● Number of PtP CMsthe number of connectable PtP CMs is only limited by the number of available slots
    Time of day
    Clock
    ● TypeHardware clock
    ● Backup time6 wk; At 40 °C ambient temperature, typically
    ● Deviation per day, max.10 s; Typ.: 2 s
    Operating hours counter
    ● Number16
    Clock synchronization
    ● supportedYes
    ● in AS, masterYes
    ● in AS, slaveYes
    ● on Ethernet via NTPYes
    Interfaces
    Number of PROFINET interfaces1
    1. Interface
    Interface types
    ● RJ 45 (Ethernet)Yes; X1
    ● Number of ports2
    ● integrated switchYes
    Protocols
    ● IP protocolYes; IPv4
    ● PROFINET IO ControllerYes
    ● PROFINET IO DeviceYes
    ● SIMATIC communicationYes
    ● Open IE communicationYes; Optionally also encrypted
    ● Web serverYes
    ● Media redundancyYes; MRP Automanager according to IEC 62439-2 Edition 2.0
    PROFINET IO Controller
    Services
    — PG/OP communicationYes
    — Isochronous modeYes
    — Direct data exchangeYes; Requirement: IRT and isochronous mode (MRPD optional)
    — IRTYes
    — PROFIenergyYes
    — Prioritized startupYes; Max. 32 PROFINET devices
    — Number of connectable IO Devices, max.128; In total, up to 256 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
    — Of which IO devices with IRT, max.64
    — Number of connectable IO Devices for RT, max.128
    — of which in line, max.128
    — Number of IO Devices that can be simultaneously activated/deactivated, max.8; in total across all interfaces
    — Number of IO Devices per tool, max.8
    — Updating timesThe minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
    Update time for IRT
    — for send cycle of 250 µs250 μs to 4 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 625 µs of the isochronous OB is decisive
    — for send cycle of 500 µs500 μs to 8 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 625 µs of the isochronous OB is decisive
    — for send cycle of 1 ms1 ms to 16 ms
    — for send cycle of 2 ms2 ms to 32 ms
    — for send cycle of 4 ms4 ms to 64 ms
    — With IRT and parameterization of "odd" send cyclesUpdate time = set "odd" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs)
    Update time for RT
    — for send cycle of 250 µs250 µs to 128 ms
    — for send cycle of 500 µs500 µs to 256 ms
    — for send cycle of 1 ms1 ms to 512 ms
    — for send cycle of 2 ms2 ms to 512 ms
    — for send cycle of 4 ms4 ms to 512 ms
    PROFINET IO Device
    Services
    — PG/OP communicationYes
    — Isochronous modeNo
    — IRTYes
    — PROFIenergyYes; per user program
    — Shared deviceYes
    — Number of IO Controllers with shared device, max.4
    — Asset management recordYes; per user program
    2. Interface
    PROFINET IO Device
    Services
    — PG/OP communicationYes
    — Isochronous modeNo
    — IRTNo
    — PROFIenergyYes; per user program
    — Prioritized startupNo
    — Shared deviceYes
    — Number of IO Controllers with shared device, max.4
    — Asset management recordYes; per user program
    Interface types
    RJ 45 (Ethernet)
    ● 100 MbpsYes
    ● AutonegotiationYes
    ● AutocrossingYes
    ● Industrial Ethernet status LEDYes
    Protocols
    PROFIsafeYes
    Number of connections
    ● Number of connections, max.96; via integrated interfaces of the CPU and connected CPs / CMs
    ● Number of connections reserved for ES/HMI/web10
    ● Number of connections via integrated interfaces64
    ● Number of S7 routing paths16
    Redundancy mode
    ● H-Sync forwardingYes
    Media redundancy
    — MRPYes; as MRP redundancy manager and/or MRP client; max. number of devices in the ring: 50
    — MRPDYes; Requirement: IRT
    — Switchover time on line break, typ.200 ms; For MRP, bumpless for MRPD
    — Number of stations in the ring, max.50
    SIMATIC communication
    ● S7 routingYes
    ● S7 communication, as serverYes
    ● S7 communication, as clientYes
    ● User data per job, max.See online help (S7 communication, user data size)
    Open IE communication
    ● TCP/IPYes
    — Data length, max.64 kbyte
    — several passive connections per port, supportedYes
    ● ISO-on-TCP (RFC1006)Yes
    — Data length, max.64 kbyte
    ● UDPYes
    — Data length, max.2 kbyte; 1 472 bytes for UDP broadcast
    — UDP multicastYes; Max. 5 multicast circuits
    ● DHCPNo
    ● SNMPYes
    ● DCPYes
    ● LLDPYes

    SIEMENS 6ES7511-1FK02-0AB0 WITH 2 PORT SWITCH, 60 NS BIT-PERFORMANCE, SIMATIC MEMORY CARD NECESSARY

    Quality SIEMENS 6ES7511-1FK02-0AB0 WITH 2 PORT SWITCH, 60 NS BIT-PERFORMANCE, SIMATIC MEMORY CARD NECESSARY for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Voboal Industrial Automation Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)